Trailer Mounted Portable Incinerator for Secure Contraband Destruction in the United States

Trailer Mounted Portable Incinerator for Secure Contraband Destruction in the United States

Law enforcement agencies across the United States face continuous challenges in managing seized contraband, particularly illegal drugs and other prohibited goods. Safe disposal requires not only complete and irreversible destruction but also strict regulatory compliance and minimized security risks. A trailer mounted portable incinerator delivers a secure, on-site solution—eliminating the need to transport hazardous materials off-location while ensuring cost-effective, environmentally responsible destruction.

This mobile evidence destruction system is engineered to meet state and federal requirements for throughput, combustion performance, portability, and operational safety.


Waste Types and Processing Method

Accepted Waste Types

  • Illegal drugs and narcotics

  • Prohibited goods and sensitive materials

  • Confiscated evidence requiring full destruction
    (Non-hazardous solid materials)

Treatment Method

  • High-temperature thermal incineration

  • Automatic destruction cycle with PLC-controlled heat-up, hold, and cool-down process

  • On-site processing eliminates risks of diversion, leakage, and theft during transport


Destruction Performance and Capacity

The system is designed specifically for law enforcement evidence destruction:

Specification Requirement Provided
Waste throughput ≥ 50 lb/hr (25 kg/hr) Yes
Primary chamber volume ≥ 25 ft³ 25 ft³ (710 L)
Secondary chamber volume ≥ 20 ft³ 20 ft³ (570 L)
Max temperature primary ≥ 2000°F Yes
Max temperature secondary ≥ 1800°F Yes
Refractory rating ≥ 2950°F 3182°F (65% Al₂O₃ firebrick)

The combination of chamber size, temperature rating, and fuel-burn efficiency provides complete and irreversible destruction.


System Architecture

Primary Combustion Chamber

  • Volume: 710 L (0.71 m³ / 25 ft³)

  • Internal size: 105 × 85 × 80 cm

  • Side-loading door with secure lock

  • Durable refractory lining ensures long service life

Secondary Combustion Chamber

  • Volume: 570 L (20 ft³)

  • Maintains high temperature for full flue-gas oxidation

  • ≥1-second residence time ensures compliant emissions and minimal odor

Chimney & Emissions

  • Fold-down type stack for safe transport

  • Visible emissions ≤10-20% opacity (standard operating conditions)


PLC Control System

The system includes advanced automation for:

  • Temperature control and sequencing

  • Controlled burn cycle with automatic shutdown

  • Safety interlocks for over-temperature and burner management

  • Simple operator interface for trained personnel

Training materials are provided prior to delivery to ensure safe, compliant operation.


Fuel System and Burners

  • Fuel Type: Diesel Oil

  • Burners: Riello G10LC (Primary + Secondary)

  • Diesel firing capacity per burner:
    6 kg/hr | 1.9 US gallons/hr

  • Combined average consumption:
    ~10 kg/hr | 3.8 US gallons/hr (site-dependent)

A 45-gallon integrated fuel tank supports extended operational autonomy.


Mobility and Trailer Design

A fully integrated two-axle flatbed trailer transports and powers the complete system:

Element Specification
Trailer dimensions 160 × 320 cm (5.25 × 10.50 ft)
Towing requirements ≤ 14,000 lb capacity vehicle
Transportation clearance ≤ 21 ft length / 8.5 ft width / 13.6 ft height
Wheels 16″ with spare tire included
Brakes Electric, DOT-compliant
HICLOVER Heavy-duty tarpaulin cover included

All critical components remain fully attached to the trailer for immediate deployment.


Application Scenarios

This equipment is ideally suited for:

  • State and federal law enforcement agencies

  • Border security and customs control

  • Drug enforcement operations in remote or temporary locations

  • Evidence destruction at seizure points

  • Rapid-deployment emergency response units

Using a mobile approach eliminates:

  • Storage delays

  • Transport security risks

  • Third-party disposal fees

  • Chain-of-custody vulnerabilities


Compliance and Operational Benefits

Regulatory Compliance

  • Meets U.S. federal expectations for destruction of controlled substances

  • Dual-chamber incineration with controlled temperatures ensures full oxidation

  • Foldable stack complies with safety guidelines during transport

Security Advantages

  • Waste destroyed at the seizure site

  • Zero transit exposure of illegal materials

  • Direct oversight by authorized personnel

Reduced Cost and Risk

  • No reliance on external facilities

  • Decreased insurance and liability exposure

  • Operational autonomy for urgent missions


Contract and Deliverables

This equipment is supplied as a turnkey, ready-to-operate solution, including:

  • Trailer-mounted incinerator unit

  • Control panel with PLC automation

  • Startup consumables and cleaning tools

  • Personnel training (documentation and video materials included)

The Trailer Mounted Portable Incinerator offers a modernized, secure, and fully compliant approach to evidence destruction in the United States. By enabling on-site treatment of seized contraband—especially illegal narcotics—agencies gain stronger security control, improved operational efficiency, and reduced environmental and logistical risk. This system represents a highly practical investment for law enforcement organizations requiring rapid, safe, and regulatory-compliant disposal of dangerous seized materials.

Mobile: +86-13813931455(WhatsApp)

Email:     [email protected]     
Email:     [email protected] 

 

2025-12-06/18:40:37

Incinerator Items/Model

HICLOVER TS100(PLC)

 

Burn Rate (Average)

100kg/hour

Feed Capacity(Average)

150kg/feeding

Control Mode

PLC Automatic

Intelligent Sensor

Continuously Feeding with Worker HICLOVER

High Temperature Retention(HTR)

Yes (Adjustable)

Intelligent Save Fuel Function

Yes

Primary Combustion Chamber

1200Liters(1.2m3)

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Burner Type

Italy Brand

Temperature Monitor

Yes

Temperature Thermometer

Corundum Probe Tube, 1400℃Rate.

Temperature HICLOVER

Yes

Automatic Cooling

Yes

Automatic False Alarm

Yes

Automatic HICLOVER Operator(APO)

Yes

Time Setting

Yes

Progress Display Bar

3.7 in” LCD Screen

Oil Tank

200L

Chimney Type

 Stainless Steel 304

1st. Chamber Temperature

800℃–1000℃

2nd. Chamber Temperature

1000℃-1300℃

Residency Time

2.0 Sec.

Gross Weight

7000kg

External Dimensions

270x170x190cm(Incinerator Main Body)

Burner operation

Automatic On/Off

Dry Scrubber

Optional

Wet Scrubber

Optional

Top Loading Door

Optional

Asbestos Mercury Material

None

Heat Heart Technology(HHT)

Optional

Dual Fuel Type(Oil&Gas)

Optional

Dual Control Mode(Manual/Automatic)

Optional

Temperature Record

Optional

Enhanced Temperature Thermometer

Optional

Incinerator Operator PPE Kits

Optional

Backup Spare Parts Kits

Optional

Mobile Type

Optional:Containerized/Trailer/Sledge Optional